The Cold-Hand Rebound: A Homeostasis Lab

Not yet classroom-tested. This is a new lab design. Expected results, times, and costs are estimates. Run it yourself before using it with students.

A one-period lab for Biology (Unit 6: Cells and Homeostasis). When your hands get cold, they warm back up on their own once you come inside. Students cool one hand in cool water (about 15 °C, never ice) for 60 seconds, then track fingertip temperature with an infrared thermometer for 6 minutes. The recovery curve is a clear picture of negative feedback.

Simulated photo of a lab station on a black bench with a tub of cool water and a thermometer, a folded towel, a handheld infrared thermometer, a timer and a washable marker.
Simulated photo of a possible setup. This lab has not been run in a classroom yet.
Line drawing of a hand resting on a table with a dot on the index fingertip and an infrared thermometer aimed at the dot.
Mark one spot on the fingertip and aim the thermometer at the same spot every time.

Lab Synopsis

  • Setup: Groups of three take roles as subject, timer, and reader. Any student can opt out of being the subject.
  • Data: Students record a starting temperature, the temperature right after the dip, and readings every 30 to 60 seconds for 6 minutes.
  • Analysis: The fingertip warms quickly at first and then slowly levels off near its starting temperature. Students label a feedback loop (stimulus, sensor, control center, response) and explain why it is negative feedback. Groups can design a second trial with their own variable.

For background, see these lessons: Organ Systems and Stimulus and Response.

Skills Students Practice

  • Planning and running a short investigation on the human body
  • Graphing a recovery curve and describing its shape with numbers
  • Modeling a negative feedback loop

Materials (per group)

  • Infrared (no-touch) thermometer with a surface mode
  • Tub of cool water (about 15 °C) and a thermometer to check it
  • Towel, timer, washable marker

Safety

  • Cool water only, never ice water.
  • Students with Raynaud’s syndrome, a circulation condition, or any other reason should not be the subject. They can time or read instead.
  • Stop right away if a hand hurts or goes numb.

Tips for Teachers

  • Test your thermometers. Many forehead thermometers have a body mode that will not show readings below about 32 °C. You need a surface or object mode.
  • Hold the distance steady (about 2 cm) and aim at the same dot every time.
  • Discuss the limits. Fingertip temperature is not held at a fixed set point like core temperature. It reflects how much warm blood the body sends to the skin.

Downloads

Everything on ZornScience is free to use in your classroom. If this saved you some prep time, you can buy me a coffee. Always appreciated, never expected.


NGSS Alignment

This lab builds toward this Next Generation Science Standards (NGSS) performance expectation:

  • HS-LS1-3: Plan and conduct an investigation to provide evidence that feedback mechanisms maintain homeostasis.

Disciplinary core ideas: LS1.A Structure and Function (feedback mechanisms)

Science and engineering practices: Planning and Carrying Out Investigations; Analyzing and Interpreting Data

Crosscutting concepts: Stability and Change